|
This unit was only used once!!!! Just check for prices around and you will see that this is a real Good Deal!!!!Fluke 725Ex Intrinsically Safe Multi-function Process CalibratorThe Simply Powerful Intrinsic Safe Calibration Tool The new 725Ex Intrinsically Safe Multi-function Process Calibrator is powerful yet easy-to-use. Combined with one of the (8) new Fluke-700PEx pressure modules, the 725Ex is able to calibrate almost any process instrument likely to need service in an area where explosive gasses may be present. Measure and source mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Do you need to calibrate transmitters? The 725Ex split display lets you view input and output values simultaneously. For valve and I/P tests, you can source mA while measuring pressure. The 725Ex has auto-stepping and auto-ramping for remote testing, plus 25% stepping for fast linearity tests. From the moment you pick it up, the Fluke 725Ex is ready to perform. Its simple controls, without menus, make operation easy. Its memory functions make set up fast. And its rugged design lets it work as hard as you do.Measurement Accuracy Voltage DC 30.000 V 0.02%+ 2 counts (upper display) 10.000 V 0.02%+ 2 counts (lower display) 90.00 mV 0.02%+ 2 counts -10.00 mV to 75.00 mV 0.025 % + 1 count (via TC connector) Current DC 24.000 mA 0.02%+ 2 counts Resistance 0.0 to 400.0 Ω 0.1Ω (4-wire), 0.15Ω (2- and 3-wire) 401 to 1500 Ω 0.5Ω (4-wire), 1Ω (2- and 3-wire) 1500 to 3200 Ω 1Ω (4-wire), 1.5Ω (2- and 3-wire) Frequency 2.0 to 1000.0 CPM 0.05 % + 1 count 1.0 to 1100.0 Hz 0.05 % + 1 count 1.00 to 10.00 kHz 0.05 % + 1 count Sensitivity 1 V peak-to-peak-minimum Pressure Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules. (for detailed specifications refer to pressure modules in options and accessories) Modules available for differential, gage, vacuum, absolute, dual and high pressure. Source Accuracy Voltage DC 100.00 mV 0.02%+2 counts 10.000 V 0.02%+2 counts -10.00 mV to 75.00 mV 0.025 % + 1 count (via TC connector) Current DC 24.000 mA (Source) 0.02%+ 2 counts 24.000 mA (Simulate) 0.02%+ 2 counts Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) 401 to 1500 Ω 0.5 Ω(excitation current 0.05 to 0.8 mA) 1500 to 3200 Ω 1 Ω(excitation current 0.05 to 0.4 mA) Frequency 2.0 to 1000.0 CPM 0.05% 1.0 to 1100.0 Hz 0.05% 1.00 to 10.00 kHz 0.25% Waveform: 5 V p-p squarewave, -0.1 V offset RTDs and Thermocouples Measure Accuracy: NI-120 0.2 °C PT-100 (385) 0.33 °C PT-100 (393) 0.3 °C PT-100 (JIS) 0.3 °C PT-200 (385) 0.2 °C PT-500 (385) 0.3 °C PT-1000 (385) 0.2 °C Resolution: 0.1 °C J: 0.7 °C K: 0.8 °C T: 0.8 °C E: 0.7 °C R: 1.8 °C S: 1.5 °C B: 1.4 °C L: 0.7 °C U: 0.75 °C N: 0.9 °C Resolution J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F XK 0.6°C BP 1.2°C Source Accuracy: NI-120 0.2 °C PT-100 (385) 0.33 °C PT-100 (393) 0.3 °C PT-100 (JIS) 0.3 °C PT-200 (385) 0.2 °C PT-500 (385) 0.3 °C PT-1000 (385) 0.2 °C Resolution: 0.1 °C Note: Accuracy stated for 4-wire measurement. J: 0.7 °C K: 0.8 °C T: 0.8 °C E: 0.7 °C R: 1.4 °C S: 1.5 °C B: 1.4 °C L: 0.7 °C U: 0.75 °C N: 0.9 °C Resolution J, K, T, E, L, N, U: 0.1 °C, B, R, S: 1 °C XK 0.6°C BP 1.2°C Specifications Ramp Functions Source functions: Voltage, current, resistance, frequency, temperature Ramps Slow ramp, Fast ramp, 25% step-ramp Loop Power Function Voltage: 12 V Accuracy: 10% Maximum current: 22 mA, short circuit protected Step Functions Source functions: Voltage, current, resistance, frequency, temperature Steps 25% of range, 100% of range Safety Specifications Agency Approvals ATEX II 1 G EEx ia IIB 171°C I.S. Class I, Division 1 Groups Mechanical & General Specifications Size 130 x 236 x 61 mm 5.188" x 9.291" x 2.402" Weight 0.85 kg (1.874 lbs.) Batteries 4 AA alkaline batteries Battery Replacement Separate battery compartment, accessible without breaking calibration seal Side port connections Pressure module connector
Place a Bid!
|